Siemens SITRANS WW100 Operating Instructions Manual

Siemens SITRANS WW100 Operating Instructions Manual

Weighfeeders
Hide thumbs Also See for SITRANS WW100:

Advertisement

Quick Links

SITRANS
Weighfeeders
SITRANS WW100
Operating Instructions
7MH7180-....(SITRANS WW100)
06/2018
A5E33560618-AC
Introduction
Safety information
Description
Installing
Calibrating
Connecting
Commissioning
Maintenance
Troubleshooting
Technical data
Dimension drawings
1
2
3
4
5
6
7
8
9
10
11

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SITRANS WW100

  • Page 1 Introduction Safety information Description SITRANS Installing Weighfeeders SITRANS WW100 Calibrating Connecting Operating Instructions Commissioning Maintenance Troubleshooting Technical data Dimension drawings 7MH7180-..(SITRANS WW100) 06/2018 A5E33560618-AC...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Changing the conveyer belt ....................28 Belt tension ..........................29 Belt tracking ...........................29 Telescoper adjustment......................30 Weigh deck alignment......................31 Quick startup overview......................32 Load cell replacement ......................32 7.9.1 Removing old load cell ......................32 7.9.2 Installing new load cell ......................33 7.9.3 Recalibration ..........................34 SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 4 Belt care ..........................37 Troubleshooting............................39 Mechanical troubleshooting ....................39 9.1.1 Zero Drift, non-repeatability, or non-linearity................39 Technical data ............................41 10.1 Specifications .........................41 Dimension drawings ...........................43 11.1 Open unit..........................43 11.2 Open horseshoe........................43 11.3 Open dust hood........................44 11.4 Enclosed unit..........................44 Index................................45 SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 5: Introduction

    Specific information for your weighfeeder model is also included with the product such as testing documents. The drive system for the servo gear motor of the SITRANS WW100 is a Sinamics S120 control unit. All instruction manuals pertaining to the drive components can be found in the companion manual appendix on the documentation CD.
  • Page 6 Introduction 1.1 The manual SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 7: Safety Information

    • working on or around the load cell(s) • working on or around the speed sensor • working on or around the drive components • working on or around the motor • placing or removing the calibration test chain SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 8 Safety information 2.1 Safety and general precautions SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 9: Description

    The belt speed can be automatically adjusted to attain the correct feed rate. SITRANS WW100 comes with a weigh bridge, speed sensor, variable frequency drive (if ordered), and calibration test chain (if ordered). An integrator is required to complete the system.
  • Page 10 Description 3.2 WW100 Operation Enclosed unit Open unit SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 11: Installing

    When lifting the weighfeeder, connect to the lifting points at the top of the unit or structural frame, and follow local governing code for lifting/hoisting. Perform a thorough and systematic inspection of containers immediately upon receipt of your Siemens weighfeeder. The containers are packed to separate each item and provide protection during shipping. Note Do not remove equipment from shipping crates or boxes until you check for possible shipping damage.
  • Page 12 9. Before starting the weighfeeder, make a final check to see that the conveyor belt is free of all tools and foreign objects, and that the infeed/skirtboards are not pinching against the belt. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 13: Electrical Installation For Servo Driven Models

    WW100 Weigh‐ feeder. The most common change for this application would be the maximum RPM (Belt Speed) of the weighfeeder (P2000), and possibly the Reversal of Belt Direction (P1113), if required. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 14 MMC card. 1. Ensure all power sources to the drive are switched OFF. 2. Insert the pre-programmed MMC into the card slot located below the BOP Display and ensure the card locks into place. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 15 – The application will be set for a maximum motor speed of 2500 RPM, approximately 50 FPM or 0.254 meters/second. Refer to P2000 - Maximum RPM (Page 17) to effectively set the maximum RPM for the application. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 16: Switching Units

    1. Set S120 display to drive number 01 (see Switching units (Page 16)). 2. Use arrows to navigate to P0003. 3. Press so the current parameter value is displayed. 4. Press to activate edit mode (display will flash). SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 17: Parameters

    Design Rate, Design Speed, and Design Load. You are interested in the Design Speed: this will aid in setting the Maximum RPM – P2000. Calculating P2000 Design Speed P14 refers to Parameter 14 of the Siemens integrator BW500. Please see the Technical Report supplied with the weighfeeder. Imperial: P2000 = Design Speed (P14-BW500) * k Factor (47.28702)
  • Page 18 7. To save this new setting, press and hold for 3 seconds. The display will begin to flash indicating the RAM to ROM function is active. This will perform a RAM to ROM backup of all parameters. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 19: Additional Notes And Important Information

    Automatic mode enable signals as well as the Analog Speed reference signals. Each of the labeled inputs has been programmed into an AND/OR gate function, and therefore is required for operation of the drive. A brief description below will help explain the input requirements: SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 20 DC power source. In turn, the dual channel digital output of F-DO 0(16) is wired in series to the corresponding control relays (refer to sche‐ matics) which function as a cutout of the Mains Power in the event of an Emer‐ gency Stop situation. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 21 System Alarms: alarms that will not affect the functioning of the Drive but only be displayed. These will continue to be displayed until the condition clears. Once the condition is cleared, the alarm will clear from the display. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 22 Installing 4.2 Electrical installation for servo driven models SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 23: Calibrating

    Perform the span calibration as described in the Calibration section of the integrator instruction manual. Note This calibration should be at least three belt revolutions or five minutes, whichever is longer. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 24 Calibrating 5.3 Span Refer to the illustration below for calibration chain placement. After the span calibration has been completed, remove the test chain and store it. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 25: Connecting

    EXC (+ to +, - to -) or cut and covered, but not wrapped together as this will short the cell. Note Standard wiring shown, consult wiring diagrams for optional electrical connections. On hazardous rated versions the termination box may appear different than shown. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 26 Connecting SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 27: Commissioning

    Disregard for horseshoe-style infeeds. The shear gate on the inlet of the weighfeeder needs to be set to allow the maximum feed rate capacity required. Consult your Siemens representative if feed rate changes are required. Skirtboards The skirtboards have been factory set to proper specifications. Note that near the inlet, the skirtboards are very close to the belt.
  • Page 28: Changing The Conveyer Belt

    4. To make the belt change easier, remove the belt scraper counterweight located at the discharge end of the conveyor. 5. Move the belt out from the side guide roller. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 29: Belt Tension

    Before attempting to track the belt, be sure: • belt scraper is in place • belt tension is near guidelines suggested in Belt tension (Page 29). • weighfeeder is level and true • installation has not warped or twisted the frame SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 30: Telescoper Adjustment

    5. Re-tighten the jam nut located on the telescoper to maintain the new telescoper position after completing the tracking procedure. 6. If you are having problems tracking the belt, consult your Siemens representative. Common causes of belt tracking problems are: uneven or improperly distributed product loading, twisted frame, or product buildup on head or tail pulleys.
  • Page 31: Weigh Deck Alignment

    Use a spirit level to level the load cells. ① ③ Belt direction Load cell base locking screws ② Alignment string/wire Run string to ensure alignment is +1/32" (+0.8 mm) to 0" (0 mm) aligned with approach and retreat slider beds. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 32: Quick Startup Overview

    Note Please read and understand all of the instructions before proceeding with the replacement. Contact your Siemens representative for assistance if you have any questions or problems. 7.9.1 Removing old load cell 1.
  • Page 33: Installing New Load Cell

    6. Route the load cell cable to the junction box and connect the load cell according to the supplied interwiring diagram. Note Once the load cell has been replaced, check the weigh deck alignment with the approach and retreat slider beds. Alignment should be +1/32" (+0.8 mm) to 0" (0 mm). SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 34: Recalibration

    4. Re-check zero calibration. Run another zero calibration and record the results. Verify that the zero repeated to the same value recorded in step 2. 5. Confirm calibration with material test as described in the integrator manual, if possible, before placing the weighfeeder back in operation. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 35: Maintenance

    Check for wear and proper belt con‐ Weekly Clean and replace as required ers, scraper, tact plow Belt tension‐ Ensure roller rotates freely and re‐ Weekly Replace as required er roller move material buildup SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 36: General Maintenance

    Load cell care The load cell shipping bolt(s) should be installed whenever the weighfeeder is moved as an extra safety measure during the storage period. Do not forget to remove the shipping bolt(s) upon re-installation. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 37: Gear Reducer

    Reduce belt tension to a minimum to prevent belt damage and re-adjust belt tension at re- installation. Note Do NOT store the weighfeeder in direct sunlight, as this will cause premature breakdown of the belt. SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 38 Maintenance 8.4 Weighfeeder storage recommendations SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 39: Troubleshooting

    Note If you have difficulty determining the cause of the problem, contact your Siemens representative. Be sure to have the Model Number and Serial Number of your system and all of the calibration and setup parameters available before calling.
  • Page 40 Troubleshooting 9.1 Mechanical troubleshooting SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 41: Technical Data

    Belt cleaning PE-HD blade type with counterweight at the head pulley for cleaning product side of belt PE-HD blade type return plow at tail pulley Optional belt cleaning brush on product side of belt SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 42 IP66, including PTC, corrosion resistant Aluminum housing, sealed surface, complies with FDA. Shipping weight Open: 91 kg (200 lbs) Enclosed: 181 kg (400 lbs) maximum Approvals Declaration of incorporation of partly completed machinery acc. directive 2006/42/EC. Meets FDA requirements for food processing SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 43: Dimension Drawings

    (41.6") 11.2 Open horseshoe 317.5 mm 838 mm Inlet (12.5") (33") Discharge 416.6 mm (16") 216 mm 172 mm 406 mm (8.5) (16") (6.8") 917.5 mm 368 mm (36.1) (14.5") 1 056.5 mm (41.6") SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 44: Open Dust Hood

    Inlet Discharge (33“) 482 mm (19“) 368.3 mm (14.5”) 127 mm 610 mm 86.5 mm (5“) (24“) (3.4”) 406.4 mm 108.8 mm 387 mm 710 mm (16”) (4.3”) (28“) (15.25“) 1 225.6 mm (48.3”) SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 45: Index

    Operating range, 41 Operating temperature, 41 Drive, 42 Preventative maintenance, 35 Electrical Preventative maintenance program, 11 storage, 37 Program sheet, 23 Pulleys, 41 PVC seal strips, 28 Feed rate, 27 Framework, 41 Quick startup, 32 SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...
  • Page 46 Static weighing, 9 Storing a weighfeeder, 36 Temperature material, 41 Tensioner roller, 36 Test chain, 23 Test load, 23 Units, 9 Variable frequency drive, 9 Weigh bridge, 9 Weighfeeders How they work, 9 Zero calibration, 23 SITRANS WW100 Operating Instructions, 06/2018, A5E33560618-AC...

Table of Contents