Dr 16 Simulation (Belt Speed And Belt Load); Value For Belt Load Simulation; Value For Belt Speed Simulation - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

8.16

DR 16 Simulation (belt speed and belt load)

The belt load and belt speed can be simulated using an input via data record DR 16. The
SIWAREX module must first be released for simulation mode in DR 3 and then activated
with command 3 or 5 or deactivated with command 4 or 6.
Procedure
● Release simulation mode in DR 3
● Send command no. 3 and/or 5 to the SIWAREX module
● Enter the belt load and/or speed to be simulated
● Transfer the data record to the SIWAREX module
Table 8- 14
Assignment of data record 16
Variable
Data record number
Length
Application
Version identifier
Value for belt load
simulation (Page 115)
Value for belt speed
simulation (Page 115)
Reserve
Reserve
8.16.1

Value for belt load simulation

Only use values for the belt load which are within the measuring range of the scale. The
word "TEST" is displayed on the main display during simulation and a status bit is set.
8.16.2

Value for belt speed simulation

Only use values for simulation of the belt speed which are within the speed range of the belt.
The word "TEST" is displayed on the main display during simulation and a status bit is set.
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Note
Contains no. of data record
Data record length
information
Information about which
application the data record
belongs to
Information about current
data record version
Reserve
Scale parameters and functions of the belt scale
8.16 DR 16 Simulation (belt speed and belt load)
Type
L
Rw
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
FLOAT
4
rw
SHORT
2
rw
USHORT
2
rw
USHORT
2
rw
Default
Min.
Max.
16
-
-
20
-
-
104
-
-
1
1
65635
0
-
-
0
0
-
0
0
-
0
0
-
Register
1578
1579
1580
1581
1582
1584
1586
1587
115

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents