GE 750 Instruction Manual page 252

Feeder management relay
Hide thumbs Also See for 750:
Table of Contents

Advertisement

750/760
Feeder Management Relay
Table 6–3: Cause of Events
General Event Causes
Autoreclose Reset
Breaker Closed
Clear Event Record
Clear Max Demand
Control Power On
Group 1 to 4 Active
Reset
Reset AR Count
Set Date
Set Time
Transfer Not Ready
Trigger Data Log
Pickup, Trip, Alarm, Latched Alarm, and Control Event Causes
Analog Rate 1 to 2
Analog Threshold 1/2
Breaker Failure
Breaker Operation
Current Demand
Frequency Decay
Line Undervoltage 3
Manual Close Block
to 4
Neg Seq Voltage
Neutral Current Level
Neutral Time OC 1 / 2
Out of Sync
Phase Dir Reverse
Phase Inst OC 1 and 2 Phase Time OC 1
Power Factor 2
Pulse Output
Senstv Gnd Time OC
Senstv Gnd Inst OC
Underfrequency 1
Underfrequency 2
Logic Input Event Causes
52a Contact
52b Contact
Block Freq Decay
Block Gnd Inst OC
Block Neg Seq Time
Block Neg Seq Volt
Block Neutral OC
Block Neutral Time
OC 1
Block Phase OC
Block Phase Time OC
1
Block Restoration
Block Sens Gnd Inst
OC
Block Trip Count
Block Undervolt 1 to 4 Block Underfreq 1 and
Bus Tie Connected
Bypass Synchrocheck
Cold Load Pickup
Incomer 1 Closed
Remote Close
Remote Open
Setpoint Group 3
Setpoint Group 4
Trigger Data Log
Trigger Trace
Warning Event Causes
A/D Virtual Ground
Analog Output +32V
Factory Service
FLASH Corrupt
Internal Temp
IRIG-B Failure
Relay Not Ready
RTC Crystal
1
The coil monitor name as programmed is displayed.
2
The pulse output quantity name as programmed is displayed.
3
For User Inputs A through T, the user-defined name is displayed
6–18
Breaker Not
Connected
Close Breaker
Open Breaker
Reset AR Shot Rate
Shots Reduced to 1(3) Shots Reduced to L/O
Trigger Trace
Apparent Power
Demand
Bus Undervoltage 1 to
2
Ground Dir Reverse
Neg Seq Dir Reverse
Neutral Dir Reverse
Overfrequency
2
Reactive Power
Demand
Trip Coil Monitor
3
User Input A to T
Block 1 Trip
Block Gnd Time OC
Block Neutral Disp
Block Neutral Time
OC 2
Block Phase Time OC
2
Block Sens Gnd OC
2
Cancel Reclosure
Incomer 2 Closed
Remote Reset
Simulate Fault
3
User Input A to T
Clock Not Set
Force Analog Out
Not Calibrated
Simulation Mode
http://www.GEmultilin.com
A4 Event Recorder
Breaker Open
Clear Energy Use
Cls From Transfer
Control Power Off
Reclosure 1 to 4
Reclosure Lockout
Reset Arc Current
Reset Trip Counter
Transfer Initiated
Trip From Transfer
Arcing Current
Autoreclose Rate
1
Close Coil Monitor
Cold Load P/U Block
Ground Inst OC
Ground Time OC
Neg Seq Inst OC
Neg Seq Time OC
Neutral Displacement
Neutral Inst OC 1/2
Overvoltage 1 and 2
Phase Current Level
Phase Time OC 2
Power Factor 1
Real Power Demand
Sens Gnd Dir Reverse
Trip Counter
UFreq Restore Init
UVolt Restore Init
VT Failure
Block 2 Close
Block All OC
Block Ground OC
Block Neg Seq Inst
Block Neutral Inst OC
Block Neutral Inst OC
1
2
Block Phase Inst OC 1 Block Phase Inst OC 2
Block Reclosure
Block Reset
Block Sens Gnd Time
Block Transfer
OC
Breaker Connected
Bus Tie Closed
Cls From Incomer 1
Cls From Incomer 2
Initiate Reclosure
Local Mode
Selected To Trip
Setpoint Group 2
Source Trip
Start Demand
Interval
UV On Other Source
Xfmr Lockout
Dry Contact +32V
EEPROM Corrupt
Force Relays
Internal RS485
Pickup Test
Prototype Software
GE Multilin