PARAMETERS MENU
Table 9: Motor nameplate parameters
Index
Parameter
Motor Nominal Volt-
P3.1.1.1
age
Motor Nominal Fre-
P3.1.1.2
quency
Motor Nominal
P3.1.1.3
Speed
Motor Nominal Cur-
P3.1.1.4
rent
P3.1.1.5
Motor Cos Phi
Motor Nominal
P3.1.1.6
Power
P3.1.1.7
Motor current limit
P3.1.1.8
Motor type
24-HOUR SUPPORT +358 (0)201 212 575 · EMAIL: VACON@VACON.COM
Min
Max
Unit
Varies
Varies
V
8.00
320.00
Hz
24
19200
rpm
Varies
Varies
A
0.30
1.00
Varies
Varies
kW
Varies
Varies
A
0
1
Default
ID
Description
Find the value U
the nameplate of the
motor.
Varies
110
Find out if the motor
connection is Delta or
Star.
Find the value f
50 / 60
111
nameplate of the
motor.
Find the value n
Varies
112
the rating plate of the
motor.
Find the value I
Varies
113
nameplate of the
motor.
Find the value on the
Varies
120
nameplate of the
motor.
Find the value I
Varies
116
nameplate of the
motor.
Maximum motor cur-
rent of the AC drive
Varies
107
Make a selection of
what motor type is
used.
0
650
0 = asynchronous
induction motor
1 = PM synchronous
motor
VACON · 55