Io#1 High Level (Id=1302); Io#1 Low Level (Id=1303); Io#1 Logic Operand (Id=1304); Io#1 Averaging Length (Id=1305) - Teltonika FM1100 User Manual

Hide thumbs Also See for FM1100:
Table of Contents

Advertisement

8.7.3 IO#1 High level (ID=1302)

Parameter defines high value of triggered IO property. This parameter is
used to set thresholds for IO properties to generate events.
Minimu
Maximu
m value
m value
-
214748364
2147483648
8

8.7.4 IO#1 Low level (ID=1303)

Parameter defines low value of triggered IO property. This parameter is
used to set thresholds for IO properties to generate events.
Minimu
Maximu
m value
m value
-
214748364
2147483648
8

8.7.5 IO#1 logic operand (ID=1304)

Parameter defines when event is sent: 0: on range exit, 1: on range
entrance, 2: both, 3: monitoring.
Minimal
Maximu
value
m value
0
3

8.7.6 IO#1 averaging length (ID=1305)

Parameter defines IO property sample length to average. If no averaging
needed default value is 1.
IO#1 averaging length
Recommen
Goes with (depends on)
ded value
IO#1 property parameter
IO#1 priority (ID=1301)
1
IO#1 Low level (ID=1303)
IO#1 logic operand (ID=1304)
IO#1 averaging length
Recommen
Goes with (depends on)
ded value
IO#1 property parameter
IO#1 priority (ID=1301)
0
IO#1 High level (ID=1302)
IO#1 logic operand (ID=1304)
IO#1 averaging length
Recommen
Goes with (depends on)
ded value
IO#1 property parameter
IO#1 priority (ID=1301)
3
IO#1 High level (ID=1302)
IO#1 Low level (ID=1303)
IO#1 averaging length
(ID=1305)
parameters
(ID=1300)
(ID=1305)
parameters
(ID=1300)
(ID=1305)
parameters
(ID=1300)
(ID=1305)
Value
type
S32
Value
type
S32
Value
type
S8
63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents