Autogeofence Event Priority (Id=1103); Autogeofence Event Generating (Id=1104); Radius (Id=1105); Accelerometer Parameters - Teltonika FM1000 ST User Manual

Table of Contents

Advertisement

Minimum
Maximum
value
value
0
65535

9.6.37 AutoGeofence event Priority (ID=1103)

Parameter defines AutoGeofence event priority: 0 is low, 1 – high.
Minimum
Maximum
value
value
0
1

9.6.38 AutoGeofence event generating (ID=1104)

Generate event: 0 – no event; 1 – on entering zone; 2 – on exiting zone; 3 – on both.
Minimum
Maximum
value
value
0
3

9.6.39 Radius (ID=1105)

Parameter represents radius of circle with center device coordinates after activating
AutoGeofence feature.
Minimum
Maximum
value
value
0
1000000
9.7

Accelerometer parameters

9.7.1

Acceleration range configuration (ID=1290)

Parameter represents range of movement detection in G force.
Minimum
Maximum
value
value
2
16
9.7.2

Movement filter start (ID=1293)

Parameter represents how long it takes to generate movement event in seconds.
Minimum
Maximum
value
value
1
60
9.7.3

Movement filer stop (ID=1294)

Parameter represents how long it takes to change movement I/O element state from 1 to 0
in seconds.
Recommended
Goes with (depends on)
value
60
Enable/Disable (ID=1101)
Recommended
Goes with (depends on)
value
Enable/Disable (ID=1101)
1
AutoGeofence event generating
Recommended
Goes with (depends on)
value
Enable/Disable (ID=1101)
2
AutoGeofence event Priority
Recommended
Goes with (depends on)
value
100
Enable/Disable (ID=1101)
Recommended
Goes with (depends on)
value
2
Ignition Source (ID=1003)
Recommended
Goes with (depends on)
value
0
Ignition Source (ID=1003)
parameters
parameters
(ID=1104)
parameters
(ID=1103)
parameters
parameters
parameters
Value
type
U16
Value
type
U8
Value
type
U8
Value
type
U32
Value
type
U32
Value
type
U32
76