I/O#1 Event Only (Id=50004); I/O#1 Averaging Length (Id=50005); I\O Elements Parameters And Types - Teltonika FMT100 User Manual

Tracking terminal with gnss and gsm
Hide thumbs Also See for FMT100:
Table of Contents

Advertisement

6.13.1.5 I/O#1 Event only (ID=50004)

Parameter defines whether element should be sent only when event is generated. Possible
values:
1 – Yes (parameter ID and value is sent when event is generated);
0 – No (parameter ID and value is sent in every record).
Minimal
Maximum
value
value
0
1

6.13.1.6 I/O#1 averaging length (ID=50005)

Parameter defines I/O property sample length to average. If no averaging needed default
value is 1.
Minimum
Maximum
value
value
0
2147483647 1
Other I/O property elements can be configured in same logic. All I/O element parameters
are listed in the next table.
6.13.2
Parameter
Parameter
ID
Type
50000
Uint8
50001
Uint8
50002
Uint8
50003
Uint8
50004
Uint8
50005
Uint16
7000
Uint8
8000
String
50010
Uint8
50011
Uint8
50012
Uint8
50013
Uint8
50014
Uint8
Recommended
Goes with (depends on)
value
parameters
I/O#1 priority (ID=50000)
I/O#1 logic operand (ID=50001)
I/O#1 High level (ID=50002)
0
I/O#1 Low level (ID=50003)
I/O#1 Event only (ID=50004)
I/O#1 averaging length (ID=50005)
Recommended
Goes with (depends on) parameters
value
I/O#1 priority (ID=50000)
I/O#1 logic operand (ID=50001)
I/O#1 High level (ID=50002)
I/O#1 Low level (ID=50003)
I/O#1 Event only (ID=50004)
I/O#1 averaging length (ID=50005)

I\O elements parameters and types.

Value range
Default value
Min
1
0
5
0
0
0
0
0
0
0
10
0
0
0
0
0
1
0
5
0
0
0
0
0
0
0
Parameter name
Max
3
Ignition Priority
6
Ignition Operand
1
Ignition High level
1
Ignition Low level
1
Ignition Event only
65535
Ignition Average
10
Send SMS
160
SMS Text
3
Movement Priority
6
Movement Operand
1
Movement High level
1
Movement Low level
1
Movement Event only
Value
type
S8
Value
type
S32
78

Hide quick links:

Advertisement

Table of Contents
loading