6.12.2 I/O#1 priority (ID=50001)
Parameter defines when event is sent: 0 – on range exit, 1 – on range entrance, 2 – both,
3 – monitoring, 4 – hysteresis, 5 – on changes, 6 – on delta change.
Minimum
Maximum
value
value
0
6
6.12.3 I/O#1 High level (ID=50002)
Parameter defines high value of triggered I/O property. This parameter is used to set
thresholds for I/O properties to generate events.
Minimum
Maximum
value
value
-
214748364
21474836
7
47
6.12.4 I/O#1 Low level (ID=50003)
Parameter defines low value of triggered I/O property. This parameter is used to set
thresholds for I/O properties to generate events.
Minimum
Maximum
value
value
-
214748364
21474836
7
47
6.12.5 I/O#1 Event only (ID=50004)
Parameter defines when IO element value is sent: 0 – with every AVL packet, 1 – on event
only. On event means that IO element value is included to AVL packet only when this particular
event happens. With regular, periodic records such IO element value is not included.
Recommended
value
I/O#1 property parameter priority
0
I/O#1 Event only (ID=50004)
I/O#1 averaging length (ID=50005)
Recommended
value
I/O#1 property parameter priority
1
I/O#1 averaging length (ID=50005)
Recommended
value
I/O#1 property parameter priority
0
I/O#1 High level (ID=50002)
I/O#1 Event only (ID=50004)
I/O#1 averaging length (ID=50005)
Goes with (depends on)
parameters
Ignition (ID=50000)
I/O#1 High level (ID=50002)
I/O#1 Low level (ID=50003)
Goes with (depends on)
parameters
Ignition (ID=50000)
I/O#1 priority (ID=50001)
I/O#1 Low level (ID=50003)
I/O#1 Event only (ID=50004)
Goes with (depends on)
parameters
Ignition (ID=50000)
I/O#1 priority (ID=50001)
Value
type
S8
Value
type
S32
Value
type
S32
83