Technical Data

Temperatures

Min. operating temperature
Max. operating temperature
Overtemperature shutdown
by thermostat
Max. operating temperature
of filling valve (option)
P/N 7146386A
CAUTION: The maximum operating temperature of the installed gun and
the other heated system components should be considered when setting
temperatures on the melter control panel.
+ 40 °C
+ 230 °C
+ 260 °C
+ 230 °C
Ni 120
Fig. 9-1
Hose receptacles
VBN w/o Control System
+100 °F
+450 °F
+480 °F
+450 °F
Pt 100