Unintended Use − Examples; Residual Risks - Nordson VersaBlue VBN 50 Manual

Adhesive melters vbn without controller
Table of Contents

Advertisement

2-2
Introduction
Unintended Use − Examples −

Residual Risks

P/N 7146386A
The melter may not be used under the following conditions:
S
In defective condition
S
Without insulation blanket and protective panels
S
With electrical cabinet door open
S
With tank lid open
S
In a potentially explosive atmosphere
S
When the values stated under Technical Data are not complied with.
The melter may not be used to process the following materials:
S
Polyurethane hot melt adhesive (PUR)
S
Explosive and flammable materials
S
Erosive and corrosive materials
S
Food products.
In the design of the unit, every measure was taken to protect personnel
from potential danger. However, some residual risks can not be avoided:
S
Risk of burns from hot material.
S
Risk of burns when filling the tank, from the tank lid, and from the tank
lid supports.
S
Risk of burns when conducting maintenance and repair work for which
the melter must be heated up.
S
Risk of burns when attaching and removing heated hoses.
S
Material fumes can be hazardous. Avoid inhalation.
S
Risk of damage to cables/lines belonging to the customer, if they were
installed such that they come into contact with hot or rotating parts.
S
The safety valve may malfunction due to hardened or charred material.