Technical Data - Nordson VersaBlue VBN 50 Manual

Adhesive melters vbn without controller
Table of Contents

Advertisement

General Data
Storage temperature
Min. ambient temperature
Max. ambient temperature
Humidity
Max. operating height
Type of heating
Possible temperature
sensors
Measuring precision
Material pressure
Default:
Viscosity range
Degree of protection
Noise emission
(at a distance of 1 m)
Motor type
Gear box type
Motor/pump speed setting
range
Heatup time
Melting capacity
E 2008 Nordson Corporation
−45 °C to +75 °C
− 5 °C
+ 50 °C
10 to 95 %, not condensing
3,000 m
Cast-in electrical resistance heating elements
Ni 120
Pt 100
" 1 °C
5 to 85 bar
The pressure control valve is preset at the factory.
35 bar
1 to 50 Pa s
IP 54
1 motor:
60 dB(A)
2 motors:
62 dB(A)
3 motors:
64 dB(A)
4 motors:
66 dB(A)
3 ph AC motor
Helical gear
-1
1.0 to 100 min
To prevent excessive wear, the motor/pump speed should not
continuously fall below 5 min
-1
80 min
(rpm).
< 45 minutes
1 tank full per hour
VBN w/o Control System

Technical Data

− 49 °F to + 167 °F
+ 23 °F
+120 °F
9840 ft
" 1 °F
500 to 8 500 kPa
3500 kPa
1 000 to 50 000 cP
5 motor:
6 motors:
7 motors:
8 motors:
-1
(rpm) or continuously exceed
9-1
Technical Data
Section 9
(1 digit)
73 to 1 233 psi
508 psi
68 dB(A)
70 dB(A)
72 dB(A)
74 dB(A)
P/N 7146386A

Advertisement

Table of Contents
loading

Table of Contents