General Data
Storage temperature
Min. ambient temperature
Max. ambient temperature
Humidity
Max. operating height
Type of heating
Possible temperature
sensors
Measuring precision
Material pressure
Default:
Viscosity range
Degree of protection
Noise emission
(at a distance of 1 m)
Motor type
Gear box type
Motor/pump speed setting
range
Heatup time
Melting capacity
E 2008 Nordson Corporation
−45 °C to +75 °C
− 5 °C
+ 50 °C
10 to 95 %, not condensing
3,000 m
Cast-in electrical resistance heating elements
Ni 120
Pt 100
" 1 °C
5 to 85 bar
The pressure control valve is preset at the factory.
35 bar
1 to 50 Pa s
IP 54
1 motor:
60 dB(A)
2 motors:
62 dB(A)
3 motors:
64 dB(A)
4 motors:
66 dB(A)
3 ph AC motor
Helical gear
-1
1.0 to 100 min
To prevent excessive wear, the motor/pump speed should not
continuously fall below 5 min
-1
80 min
(rpm).
< 45 minutes
1 tank full per hour
VBN w/o Control System
Technical Data
− 49 °F to + 167 °F
+ 23 °F
+120 °F
9840 ft
" 1 °F
500 to 8 500 kPa
3500 kPa
1 000 to 50 000 cP
5 motor:
6 motors:
7 motors:
8 motors:
-1
(rpm) or continuously exceed
9-1
Technical Data
Section 9
(1 digit)
73 to 1 233 psi
508 psi
68 dB(A)
70 dB(A)
72 dB(A)
74 dB(A)
P/N 7146386A