Electrical Data - Nordson VersaBlue VBN 50 Manual

Adhesive melters vbn without controller
Table of Contents

Advertisement

Electrical Data

Type designation
Available operating voltages 200 − 240 V
Permissible voltage
deviations
Operating voltage
frequency
Melter fuse protection
Key-to-line
Max. input
Max. no. of gun/hose
connections
Max. load, gun/hose
connections
Per gun or hose [W]
Per gun/hose pair [W]
Total [W]
Max. melter load [W]
Max. no. of ext. motor
controllers
Max. no. of ext. analog
pressure inputs
Max. no. of ext. digital
pressure inputs
Max. no. of channels for
Air Run-up
E 2008 Nordson Corporation
WARNING: The unit is designed for only one operating voltage. Operate
only at the operating voltage shown on the ID plate.
VBN 50
VBN 100
3-phase without neutral (Delta)
AC
380 − 415 V
3-phase with neutral (star − WYE)
AC
Power supply:" 10%
I/O:
" 10%
50/60 Hz
Refer to ID plate
0 to 10 V
DC
18
18
2 000
2 000
4 000
4 000
46 000
46 000
58 100
68 700
6
6
8
8
12
12
16
16
VBN w/o Control System
VBN 200
VBN 50/50 VBN 50/100
26
26
26
2 000
2 000
2 000
4 000
4 000
4 000
46 000
46 000
46 000
82 900
72 800
81 350
6
6
6
16
16
16
12
12
12
16
16
16
9-3
Technical Data
VBN 100/100
26
2 000
4 000
46 000
89 900
6
16
12
16
P/N 7146386A

Advertisement

Table of Contents
loading