6.3.3.3

X100 DRIVE-CLiQ interface

Table 6-14
DRIVE-CLiQ interface
Pin
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Molex, order number: 85999-3255
The maximum DRIVE-CLiQ cable length is 100 m.
6.3.3.4

X120 EP terminals / temperature sensor connection

Table 6-15
Terminal strip X120
Terminal
1
2
3
4
5
6
7
8
Max. cross-section that can be connected 1.5 mm
Notice
The KTY temperature sensor/the PTC must be connected with the correct polarity.
Equipment Manual AC Drive
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
GND (0 V)
Function
Reserved, do not use
Reserved, do not use
M
+Temp
-Temp
Reserved, do not use
EP +24 V
EP M1
2
6.3 Control Unit CU310 PN (PROFINET)
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronic ground
Technical specifications
Ground
KTY or PTC input
Ground for KTY or PTC
Safe standstill input (+)
Safe standstill input (-)