Power Modules
3.1 Power Modules Blocksize (PM340)
Line voltage 3-ph. 380 V to 480 V AC
PM340
PM340 with integrated line
filter
Rated input current
1)
with line reactor
-
- without line reactor
Resistance value of the
external braking resistor
Max. cable length to braking
resistor
Line supply connection
U1/L1, V1/L2, W1/L3
Motor connection
U2, V2, W2
DC link connection,
connection for braking
resistor DCP/R1, DCN, R2
PE connection
Max. motor cable length
2)
Degree of protection
Height
PM 340 with integrated line
filter
Depth
- PM340 with Control Unit
CU310
- PM340 with CUA31
Frame size
Weight, approx. without line
filter/
with integrated line filter
1)
2)
3-36
6SL3210-
1SE31-0UA0
6SL3210-
1SE31-0AA0
A
94
105
Ohm
≥ 15
m
15
Stud M6,
cable cross-section
that can be
connected
10 to 35 mm
Stud M6,
cable cross-section
that can be
connected
10 to 35 mm
Stud M6,
cable cross-section
that can be
connected
10 to 35 mm
at the housing with
M6 screw
m
75 (shielded)
100 (non-shielded)
IP20 or IPXXB
mm
633 (24.92)
mm
293.1 (11.53)
233.8 (9.20)
E
kg
19.8
27.1
The input current depends on the motor load and line impedance. The input currents apply for a load with the rated power (based on In)
for a line impedance corresponding to uk = 1%.
Max. motor cable length 50 m (shielded), 100 m (non-shielded), for Power Modules PM340 with integrated line filter to maintain the limit
values of EN 61800-3 Category C2.
1SE31-1UA0
1SE31-1AA0
115
129
≥ 8.2
15
Stud M8,
max. cable cross-
section that can be
connected
1 x 120 mm
or
2
2
2 x 50 mm
2
Stud M8,
max. cable cross-
section that can be
connected
1 x 120 mm
or
2
2
2 x 50 mm
2
Stud M8,
max. cable cross-
section that can be
connected
1 x 120 mm
or
2
2
2 x 50 mm
2
At the housing with
M8 screw
70 (shielded)
100 (non-shielded)
IP20 or IPXXB
934 (36.77)
405.1 (15.94)
345.8 (13.61)
F
50.7
66.7
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
1SE31-5UA0
1SE31-8UA0
1SE31-5AA0
1SE31-8AA0
151
186
168
204
≥ 8.2
≥ 8.2
15
15
Stud M8,
Stud M8,
max. cable cross-
max. cable cross-
section that can be
section that can be
connected
connected
1 x 120 mm
or
1 x 120 mm
2
2 x 50 mm
2 x 50 mm
2
Stud M8,
Stud M8,
max. cable cross-
max. cable cross-
section that can be
section that can be
connected
connected
1 x 120 mm
or
1 x 120 mm
2
2 x 50 mm
2 x 50 mm
2
Stud M8,
Stud M8,
max. cable cross-
max. cable cross-
section that can be
section that can be
connected
connected
1 x 120 mm
or
1 x 120 mm
2
2 x 50 mm
2 x 50 mm
2
At the housing with
At the housing with
M8 screw
M8 screw
70 (shielded)
70 (shielded)
100 (non-shielded)
100 (non-shielded)
IP20 or IPXXB
IP20 or IPXXB
934 (36.77)
934 (36.77)
405.1 (15.94)
405.1 (15.94)
345.8 (13.61)
345.8 (13.61)
F
F
50.7
50.7
66.7
66.7
Equipment Manual AC Drive
or
2
2
or
2
2
or
2
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents