Electrical data
Chassis format units
Standard
With line filter
Overvoltage category
Mechanical data
Vibratory load
Long-term storage
Transport
Operation
Shock load
Long-term storage
Transport
Operation
Ambient conditions
Degree of protection
Class of protection
Type of cooling
Permissible ambient temperature in operation for
line-side components and Power Modules
Permissible ambient temperature in operation for
Control Units and supplementary system
components
Climatic ambient conditions
Storage
1)
Transport
1)
Operation
Environmental class/harmful chemical
substances
Storage
Transport
Operation
Organic/biological effects
Storage
Transport
Operation
Degree of pollution
Equipment Manual AC Drive
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
Category C3 acc. to EN 61800-3.
Category C2 acc. to EN 61800-3.
III acc. to EN 60664-1
Class 1M2 acc. to EN 60721-3-1 in transport packaging.
Class 2M3 acc. to EN 60721-3-2 in transport packaging.
Test values: 10 to 58 Hz 0.075 mm; 58 to 200 Hz 9.81 m/s
Class 1M2 acc. to EN 60721-3-1 in transport packaging.
Class 2M3 acc. to EN 60721-3-2 in transport packaging.
Test values: 147.15 m/s
2
IP20 or IPXXB acc. to EN 60529; Open Type acc. to UL 508.
Class I (with protective conductor) and Class III (PELV) to EN 61140.
Internal air cooling, power units with forced air cooling using an
integrated fan.
0 °C to +40 °C without derating, maximum installation altitude 1000 m
above sea level.
40 °C to +55 °C refer to derating characteristics.
0 °C to +55 °C; maximum installation altitude 1000 m above sea level.
From an altitude of 1000 m, the max. ambient temperature decreases
by 7°C every 1000 m.
Class 1K4 acc. to EN 60721-3-1 in transport packaging.
Temperature -25 °C to +55 °C.
Class 2K4 acc. to EN 60721-3-2 in transport packaging.
Temperature -40 °C to +70 °C.
Maximum air humidity 95 % at 45 °C.
Class 3K4 acc. to EN 60721-3-3.
Temperature 0 °C to +40 °C.
Oil mist, formation of ice, moisture condensation, water drops, water
spray, water splashes and water jets are not permissible (EN 60204,
Part 1).
Class 1C2 acc. to EN 60721-3-1 in transport packaging.
Class 2C2 acc. to EN 60721-3-2 in transport packaging.
Class 3C2 acc. to EN 60721-3-3.
Class 1B1 acc. to EN 60721-3-1 in transport packaging.
Class 2B1 acc. to EN 60721-3-2 in transport packaging.
Class 3B1 acc. to EN 60721-3-3.
2 acc. to 60664-1.
(15 g) / 11 ms.
System overview
1.6 System data
(1 g).
2
1-7