5.3.1.4

Connection of the dv/dt filter

Figure 5-15
Connection of the dv/dt filter
Cable cross-sections
Table 5-19
Cable cross-sections for connected between a dv/dt filter and Power Module
dv/dt filter plus VPL
6SL3000-2DE32-6AA0
6SL3000-2DE35-0AA0
Note
The connections should be kept as short as possible.
The maximum cable length for the specified connections is is 5 m.
Equipment Manual AC Drive
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
Connection to the DC link
(DCPS / DCNS)
[mm²]
35
70
Motor-side power components
5.3 dv/dt filter
Connection between a dv/dt reactor
and voltage limiting network
(1U2, 1V2, 1W2) [mm²]
10
16
5-25