4.5 Onboard drive interface (C230-2, C240)

Signal names
Table 4-5
Signal name
A, B
RTS
P5
M5
P24
M24
Signal type
O - signal output
I/O - signal input/output
VO - voltage output
4.5
Onboard drive interface (C230-2, C240)
Connector to drive unit
Drive units with an analog interface (±10 V) or stepper motor power units with at least one
clock pulse input and direction input can be connected to the 50-pin Sub-D socket X2. Any
hybrid configuration can be used for up to four drives.
In addition, the C230-2 and C240 provide one enable signal per axis.
With the C240, this interface (X2) can also be used for standard outputs:
● 4 analog outputs
● 4 digital outputs
48
Signal names
Meaning
Data input/output (RS485)
Transmission request
5 V power supply 60 mA, short-circuit-proof
5 V reference potential
24 V supply 150 mA, short-circuit-proof, not isolated
24 V reference potential