Mounting - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Order No.
6SE6400-
Frame size
D2
W
W1
Table 4-2
Dimension data: Braking resistor, all data in mm and (inches), Part 2
Order No.
6SE6400-
Frame size
L
L1
L2
L3
D
D1
D2
W
W1
4.1.1.4

Mounting

The braking resistor is connected at terminals DCP/R1 and R2.
The braking resistors can be installed at the side next to the PM340 Power Modules. The
braking resistors for A and B frame sizes are designed as sub-chassis components. If the
PM340 Power Modules of the A or B frame sizes are operated without line reactor, the
braking resistors can also be installed under the Power Modules.
The braking resistor is positioned outside the cabinet or switchgear room. This enables the
resulting heat loss around the Power Modules / Motor Modules to be dissipated, This
reduces the level of air conditioning required.
Equipment Manual AC Drive
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
4BC05-0AA0
4BD11-0AA0
A
-
72 (2.83)
56 (2.20)
4BD21-2DA0
D
515 (20.27)
350 (13.77)
205 (8.07)
195 (7.67)
175 (6.88)
242 (9.52)
210 (8.26)
270 (10.62)
315 (12.40)
4BD12-0BA0
A
-
72 (2.83)
149 (5.86)
56 (2.20)
138 (5.43)
4BD22-2EA0
E
645 (25.39)
480 (18.89)
205 (8.07)
195 (7.67)
175 (6.88)
242 (9.52)
210 (8.26)
270 (10.62)
315 (12.40)
DC link components
4.1 Blocksize
4BD16-5CA0
B
C
-
185 (7.28)
185 (7.28)
230 (9.05)
4BD24-0FA0
F
650 (25.59)
510 (20.07)
270 (10.62)
335 (13.18)
315 (12.40)
382 (15.03)
382 (15.03)
400 (15.74)
435 (17.12)
4-5

Hide quick links: