Chassis; Description; Safety Information - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor-side power components
5.1 Motor reactors
Table 5-13
Motor reactors for Power Modules 3-ph. 380 V to 480 V AC, Part 4
Rated current
Power loss
Connection to the Power Module
Motor connection
PE connection
Max. permissible cable length between the motor reactor and motor
for line supply voltages 380 V to 400 V
for line supply voltages 401 V to 480 V
Degree of protection
Weight, approx.
Suitable for Power Module, Blocksize format
Rated current In (power) of the Power Module
Frame size
5.1.2

Chassis

5.1.2.1

Description

Motor reactors reduce the voltage stress on the motor windings by reducing the voltage
gradients at the motor terminals that occur when motors are fed from drive converters. At the
same time, the capacitive re-charging currents that additionally load the output of the Power
Module when longer motor cables are used are simultaneously reduced.
5.1.2.2

Safety information

Caution
The cooling clearances of 100 mm above and below the components must be observed.
Note
The connecting cables to the Power Module must be kept as short as possible (max. 5 m).
Caution
When using motor reactors that SIEMENS has not approved for SINAMICS, then these can
thermally damage the reactor.
Caution
The surface temperature of the motor reactors can exceed 80 °C.
Caution
The maximum permissible output frequency when motor reactors are used is 150 Hz.
5-16
Motor reactor (for a 4 kHz pulse frequency)
6SE6400-3TC14-5FD0
A
178
kW
0.47
Flat terminator for M8 cable lug
Flat terminator for M8 cable lug
M8 screw
m
200 (shielded)
300 (non-shielded)
IP00
kg
57
Type
6SL3210-1SE31-8UA0
6SL3210-1SE31-8AA0
A
178
F
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
Equipment Manual AC Drive