Option Constants: F

The following settings are made with the option constants (F constants): Settings for option boards
PG Option Setup: F1
User constants for the PG Speed Control Board are shown in the following table.
Con-
stant
Number
F1-01 PG constant
Operation
selection at
F1-02
PG open
circuit
(PGO)
Operation
selection at
F1-03
overspeed
(OS)
-38
5
Name
Description
Sets the number of PG (pulse
generator or encoder) pulses.
Sets the number of pulses
per motor revolution.
Sets the PG disconnection
stopping method.
0: Ramp to stop
(Deceleration stop using
Deceleration Time 1, C1-
02.)
1: Coast to stop
2: Fast stop (Emergency
stop using the
deceleration time in C1-
09.)
3: Continue operation (To
protect the motor or
machinery, do not
normally make this
setting.)
Sets the stopping method
when an overspeed (OS)
fault occurs.
0: Ramp to stop
(Deceleration stop using
Deceleration Time 1, C1-
02.)
1: Coast to stop
2: Fast stop (Emergency
stop using the
deceleration time in C1-
09.)
3: Continue operation (To
protect the motor or
machinery, do not
normally make this
setting.)
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0 to
600
No
No
60000
0 to 3
1
No
No
0 to 3
1
No
No
MEMO
Open
BUS
V/f
Flux
Page
Loop
Regis-
with
Vec-
Vec-
ter
PG
tor
tor
Q
No
Q
380H 6-157
A
No
A
381H 6-157
A
No
A
382H 6-157