Monitor Data - YASKAWA CIMR-F7A Instruction Manual

Varispeed f7 general purpose inverter
Hide thumbs Also See for CIMR-F7A:
Table of Contents

Advertisement

Monitor Data

The following table shows the monitor data. Monitor data can only be read.
Register No.
Inverter status
Bit 0
Bit 1
Bit 2
Bit 3
0020H
Bit 4
Bit 5
Bit 6
Bit 7
Bits 8 to B
Error details
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
0021H
Bit 8
Bit 9
Bit A
Bit B
Bit C
Bit D
Bit E
Bit F
Data link status
Bit 0
Bit 1
0022H
Bit 2
Bit 3
Bit 4
Bits 5 to F
0023H
Frequency reference (U1-01)
0024H
Output frequency (U1-02)
0025H
Output voltage reference (U1-06)
0026H
Output current (U1-03) (Unit: 1/0.1A)
0027H
Output power (U1-08)
0028H
Torque reference (U1-09)
0029H
Not used
002AH
Not used
Sequence input status
Bit 0
Bit 1
Bit 2
Bit 3
002BH
Bit 4
Bit 5
Bit 6
Bit 7
Bits 8 to F
Contents
Operation 1: Operating 0: Stopped
Reverse operation 1: Reverse operation 0: Forward operation
Inverter startup complete 1: Completed 2: Not completed
Error 1: Error
Data setting error 1: Error
Multi-function contact output (terminal M1 - M2) 1: ON 0: OFF
Multi-function PHC output 1 (terminal P1 - PC) 1: ON 0: OFF
Multi-function PHC output 2 (terminal P2 - PC) 1: ON 0: OFF
Not used
Overcurrent (OC) Ground fault (GF)
Main circuit overvoltage (OV)
Inverter overload (OL2)
Inverter overheat (OH1, OH2)
Injection brake transistor resistance overheat (rr, rH)
Fuse blown (PUF)
PID feedback reference lost (FbL)
External fault (EF, EFO)
Hardware error (CPF)
Motor overload (OL1), overtorque 1 (OL3) detected, or overtorque 2 (OL4) detected
PG broken wire detected (PGO), Overspeed (OS), Speed deviation (DEV)
Main circuit undervoltage (UV) detected
Main circuit undervoltage (UV1), control power supply error (UV2), inrush preven-
tion circuit error (UV3), power loss
Main Circuit Voltage Fault (PF), Output Open-phase (LF)
MEMOBUS communications error (CE)
Operator disconnected (OPR)
Writing data
Not used
Not used
Upper and lower limit errors
Data integrity error
Not used
Multi-function contact input terminal S1 1: ON, 0: OFF
Multi-function contact input terminal S2 1: ON, 0: OFF
Multi-function contact input terminal S3 1: ON, 0: OFF
Multi-function contact input terminal S4 1: ON, 0: OFF
Multi-function contact input terminal S5 1: ON, 0: OFF
Multi-function contact input terminal S6 1: ON, 0: OFF
Multi-function contact input terminal S7 1: ON, 0: OFF
Multi-function contact input terminal S8 1: ON, 0: OFF
Not used
Individual Functions
103
6-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading