Zero-servo Function (SPEC: E or Later Only)

The zero-servo function holds the motor when the motor is stopped in what is call a zero-servo status. This
function can be used to stop the motor even with an external force acts on the motor or the analog reference
input is offset.
The zero-servo function is enabled when one of the multi-function inputs (H1-01 to H1-06) is set to 72 (zero-
servo command). If the zero-servo command is ON when the frequency (speed) reference falls below the zero-
speed level, a zero-servo status is implemented.
Related Constants
Con-
Name
stant
Number
Used to set the frequency which
starts DC injection braking in
units of Hz when deceleration to
Zero-speed
stop is selected.
level (DC
When b2-01 is less than E1-09,
injection
b2-01
E1-09 is used to set the starting
braking start-
frequency for the DC injection
ing fre-
braking.
quency)
In flux vector control, b2-01 is
used to set the starting frequency
for the zero-speed control.
Adjust the strength of the zero-
servo lock.
Enabled when the "zero-servo
command" is set for the multi-
function input. When the zero-
servo command has been input
Zero-servo
and the frequency reference
b9-01
gain
drop below excitation level (b2-
01), a position control loop is
created and the motor stops.
Increasing the zero-servo gain in
turn increases the strength of the
lock. Increasing it by too much
will cause oscillation.
Sets the output width of the
zero-servo completion signal.
Enabled when the "zero-servo
completion (end)" is set for a
multi-function input. The zero-
servo completion signal is ON
Zero-servo
when the current position is
b9-02
completion
within the range (the zero-servo
width
start position± zero-servo com-
pletion width.)
Set the allowable position dis-
placement from the zero-servo
start position to 4 times the pulse
rate of the PG (pulse generator,
encoder) in use.
Setting
Description
Range
0.0 to
10.0
0 to 100
0 to
16383
Control Methods
Change
Open
Factory
during
V/f
Loop
Setting
Opera-
V/f
with
Vec-
tion
PG
0.5 Hz
No
A
A
5
No
No
No
10
No
No
No
Individual Functions
MEMO
BUS
Flux
Regis-
Vec-
ter
tor
tor
A
A
189H
No
A
1DAH
No
A
1DBH
145
6-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents