No.
Name
Operation when frequency refer-
L4-05
ence is missing
L5-01
Number of auto restart attempts
L5-02
Auto restart operation selection
L6-01
Torque detection selection 1
L6-02
Torque detection level 1
L6-03
Torque detection time 1
L6-04
Torque detection selection 2
L6-05
Torque detection level 2
L6-06
Torque detection time 2
L7-01
Forward drive torque limit
L7-02
Reverse drive torque limit
L7-03
Forward regenerative torque limit
L7-04
Reverse regenerative torque limit
Integral time setting for torque
L7-06
limit
Control method selection for torque limit
L7-07
during acceleration and deceleration
Protect selection for internal DB
L8-01
resistor (Type ERF)
L8-02
Overheat pre-alarm level
Operation selection after overheat
L8-03
pre-alarm
Input open-phase protection selec-
L8-05
tion
Output open-phase protection
L8-07
selection
L8-09
Ground protection selection
L8-10
Cooling fan control selection
L8-11
Cooling fan control delay time
L8-12
Ambient temperature
Table 10.7 User Constants (Continued)
Fac-
Set-
tory
No.
ting
Setting
0
L8-15
0
L8-18
*16
0
L8-32
0
N1-01
150
N1-02
0.1
N2-01
0
N2-02
150
N2-03
0.1
N3-01
200
N3-02
200
N3-03
200
N3-04
200
N5-01
200
N5-02
0
N5-03
0
N5-04
*6
o1-01
95
3
o1-02
0
o1-03
0
o1-04
1
o1-05
0
o2-01
60
o2-02
45
o2-03
Name
OL2 characteristics selection at
low speeds
Soft CLA selection
OH1 detection of Inverter's cool-
ing fan
Hunting-prevention function selec-
tion
Hunting-prevention gain
Speed feedback detection control
(AFR) gain
Speed feedback detection control
(AFR) time constant
Speed feedback detection control
(AFR) time constant 2
High-slip braking deceleration fre-
quency width
High-slip braking current limit
High-slip braking stop dwell time
High-slip braking OL time
Feed forward control selection
Motor acceleration time
Feed forward proportional gain
Response frequency for speed
command
Monitor selection
Monitor selection after power up
Frequency units of reference set-
ting and monitor
Setting unit for frequency con-
stants related to V/f characteristics
LCD brightness adjustment
LOCAL/REMOTE key enable/dis-
able
STOP key during control circuit
terminal operation
User constant initial value
User Constants
Fac-
Set-
tory
ting
Setting
1
*2
1
1
1
1.00
1.00
50
750
5
150
1.0
40
0
*6
0.178
1.0
40.00
6
10
1
0
0
3
1
1
0
35
10-