YASKAWA CIMR-F7A Instruction Manual page 121

Varispeed f7 general purpose inverter
Hide thumbs Also See for CIMR-F7A:
Table of Contents

Advertisement

Con-
Name
stant
Number
Used to set the method of
operation when the fre-
quency reference input is
less than the minimum out-
put frequency (E1-09).
0: Run at frequency refer-
Operation
ence (E1-09 not effec-
selection for
tive).
b1-05
setting E1-
1: STOP (Frequencies
09 or less
below E1-09 in the coast
to stop state.)
2: Run at min. frequency.
(E1-09)
3: Run at zero-speed (Fre-
quencies below E1-09 are
zero)
Used to set the responsive-
ness of the control inputs
(forward/reverse and multi-
function inputs.)
Read
0: Two scans every 2 ms
b1-06
sequence
(Use for fast responses.)
input twice
1: Two scans every 5 ms
(Use for possible
malfunction due to
noise.)
Used to set the operation
mode by switching to the
Remote mode using the
Local/Remote Key.
Operation
0: Run signals that are input
selection
during mode switching
after switch-
b1-07
are disregarded. (Input
ing to
Run signals after
remote
switching the mode.)
mode
1: Run signals become
effective immediately
after switching to the
Remote mode.
Used to set an operation
interlock in programming
modes.
0: Cannot operate.
Run Com-
1: Can operate (Disabled
mand selec-
when Digital Operator is
b1-08
tion in
set to select Run Com-
program-
mand (when b1-02 = 0)).
ming modes
2: Cannot operate. (Cannot
be in programming mode
during operation.)
* 0 or 1 for flux vector control.
Setting
Description
Range
0 to 3
0 or 1
0 or 1
0 to 1
0 to 2
Control Methods
Change
Open
Factory
during
V/f
Loop
Setting
Opera-
V/f
with
Vec-
tion
PG
0
No
No
No
No
1
No
A
A
0
No
A
A
0
No
A
A
User Constant Tables
MEMO
BUS
Flux
Page
Regis-
Vec-
ter
tor
tor
A
184H 6-17
A
A
185H
-
A
A
186H
-
A
A
187H
-
5-
11

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents