3T.01
Torch Connections
Connect the torch to the Power Supply. Connect only the ESAB model SL60 / Manual or SL100 / Me-
chanical torch to this power supply.
1.
Align the ATC male connector (on the torch lead) with the female receptacle. Push the male
connector into the female receptacle. The connectors should push together with a small
amount of pressure.
2.
Secure the connection by turning the locking nut clockwise until it clicks. DO NOT use the
locking nut to pull the connection together. Do not use tools to secure the connection.