Cli\System\Restarts Menu Command; Cli\System\Event Menu Command - Siemens SCALANCE W786-xPRO Operating Instructions Manual

Table of Contents

Advertisement

5.7.2.4

CLI\SYSTEM\RESTARTS menu command

Default settings and restart
With the commands in this menu, you can restore the factory settings of the device and
restart the device.
CLI\SYSTEM\RESTARTS>
Command
restart
memreset
defaults
See also
Restart menu command (Page 101)
5.7.2.5

CLI\SYSTEM\EVENT menu command

Syntax of the Command Line Interface
For each of the four possible reactions E-mail, trap, log and fault, either "E" (Enabled =
setting is enabled) or "D" (Disabled = setting is disabled) must be entered as the parameter.
If, for example, an E-mail is sent when the device restarts (first parameter "CW") and an
entry is made in the log table but neither a trap nor an error is generated, the following
command must be entered:
setec CW E D E D (for SCALANCE W-700)
setec CW D E D (for IWLAN/PB LINK)
Note
The IWLAN/PB LINK does not support E-mail. As a result, the second parameter for
enabling/disabling the E-mail option is omitted.
SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
Description
Restart the device.
Resets the factory settings and
triggers a restart (the protected
settings are not deleted).
Resets to the factory settings (the
protected settings are also
deleted).
Configuration / project engineering
5.7 Configuration with the Command Line Interface
Comment
IWLAN/
W744
W746
PB LINK
This command can be called from all menus, however
not using the shortcut commands.
After restoring the factory settings, restart manually.
W747
W78x
W78x
RR
177