Configuration / project engineering
5.7 Configuration with the Command Line Interface
5.7.2.3

CLI\SYSTEM\SERVICES menu command

Configuration options
With the commands in this menu, you select the services (SNMP, Web Based Management
etc.) with which access to the device will be possible.
CLI\SYSTEM\SERVICES>
Command
telnet [E|D]
ttimeout [E|D]
ttimeout [time in s]
ssh [E|D]
snmp [E|D]
mail [E|D]
web [E|D]
httpsonly [E|D]
ping [E|D]
psu [E|D]
ftpserv [E|D]
See also
Services menu command (Page 100)
176
Description
Enable / disable configuration of the
device over Telnet.
Enables / disables the time
restriction for a Telnet session.
Specifies the time after which a
Telnet section is closed if there is no
further input.
Enables / disables configuration of
the device over secure Telnet.
Enable / disable SNMP.
Enable / disable E-mail.
Enable / disable configuration of the
device over Web Based
Management.
Enable / disable access for
configuring only over HTTPS.
Enable / disable response of the
device to Ping.
Enable / disable access to the
device with the Primary Setup Tool.
If this access option is deactivated,
configuration data can only be read
with the Primary Setup Tool.
Enable / disable the FTP server on
the device. Required for
downloading the Signal.TXT file
generated by the Signal Recorder.
Comment
IWLAN/
W744
W746
PB LINK
Only WEB and SNMP
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
W747
W78x
W78x
RR
SCALANCE W786-xPRO

Hide quick links: