4. Seal all openings not required for cables with sealing plugs (position D in the figure
5. Fit these sealing plugs in a strain relief clamp. The lower surrounding notch must be
Figure 4-2
Points to note when connecting an oval FO cable
The oval FO cable specified for use with the SCALANCE W786 does not have a circular
cross section. As a result, remember the following points when connecting up such cables.
Gasket
Fit the supplied adhesive sealing foil at the point where the cable goes through the housing
seal. Only then will you achieve perfect sealing of the housing. Follow the steps outlined
below:
1. Remove the protective foil and wind the adhesive sealing foil completely around the oval
SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
above).
enclosed by the toothing of the strain relief clamp (as shown in the figure below). Press
the strain relief clamp into the housing until the sealing plug is located completely in the
opening of the housing seal.
Securing a sealing plug with a strain relief clamp
Note
Keep unused sealing plugs and strain relief clamps for later use.
FO cable at the appropriate position transverse to the cable.
Connecting up
4.3 Connecting the cables