Configuration / project engineering
5.6 Configuration with Web Based Management
devices you want to configure. If necessary, you may need to assign an IP address to these
devices first using the Primary Setup Tool.
How to load or save data over HTTPS
1. To load or save configuration data or the firmware, enter the name of the file from which
the data will be taken and in which the data will be saved in the relevant input box.
As an alternative, you can also use a file selection dialog that opens after you click the
"Browse..." button.
2. Start the save function by clicking the Save button. Start the load from file function by
clicking the "Load" button.
How to load or save data over TFTP
1. Enter the IP address of the TFTP server in the TFTP Server IP input box.
2. Enter the port of the TFTP server in the Port text box if the default value does not meet
your requirements.
3. Click the Set Values button before you enter any further information for saving the data.
4. Specify the name of the file (maximum 32 characters) from which the data will be taken or
where the data will be saved in the relevant input box for the configuration data or
firmware.
5. Start the save function by clicking the Save button. Start the load from file function by
clicking the Load button.
Configuration package
If security certificates for the client and/or server are installed on a client, when the
configuration is saved, the client provides the option of saving the configuration file with the
certificates as a configuration package. With the aid of the configuration package, clients can
be replicated simply; in other words, identical settings AND certificates are transferred to the
clients in one step. Just as when you download the configuration file, this is followed by a
restart. No special measures are necessary when downloading the configuration because
the SCALANCE W-700 automatically recognizes the type of configuration file.
See also
CLI\SYSTEM\LOADSAVE menu command (Page 186)
5.6.3.12

C-PLUG menu command

Information on the content of the C-PLUG
This menu command provides you with detailed information on the C-PLUG. You can also
format the C-PLUG or provide it with new content. As soon as the device is started with a C-
PLUG inserted, the SCALANCE W starts up with the configuration data on the C-PLUG.
Changes to parameters are stored on the C-PLUG and displayed over the Web and CLI.