6.3

Firmware update via WBM or CLI not possible

Cause
If there is a power failure during the firmware update, it is possible that the device is no longer
accessible using Web Based Management or the CLI.
When pressing the button, make sure you adhere to the instructions in the section "Reset
button".
Solution
You can then also assign firmware to a SCALANCE W700 using TFTP.
Follow the steps below to load new firmware using TFTP:
1. Turn off the power to the device.
2. Now press the Reset button and reconnect the power to the device while holding down the
button.
3. Hold down the button until the red fault LED (F) starts to flash after approximately 2 seconds.
4. Now release the button. The bootloader waits in this state for a new firmware file that you
can download by TFTP.
5. Connect a PC to the SCALANCE W700 over the Ethernet interface.
6. Assign an IP address to the SCALANCE W700 with the Primary Setup Tool.
7. Open a DOS box and change to the directory where the file with the new firmware is located
and then execute the command "tftp -i <ip address> PUT <firmware>". As an alternative,
you can use a different TFTP client.
8. Close the cover to ensure that the device is closed and water and dust proof.
Note
Use of CLI and TFTP in Windows 7
If you want to access the CLI or TFTP in Windows 7, make sure that the relevant functions are
enabled in Windows 7.
Result
The firmware is transferred to the device.
Note
Please note that the transfer of the firmware can take several minutes. During the transmission,
the red error LED (F) flashes.
Once the firmware has been transferred completely to the device, the device is restarted
automatically.