Connecting The Cables - Siemens SCALANCE W786-xPRO Operating Instructions Manual

Table of Contents

Advertisement

4.3

Connecting the cables

Procedure
Danger from line voltage
If the housing is not perfectly sealed, there is a danger to life due to the line voltage if the
SCALANCE W786 is subjected to spray water or dampness. Make sure that you keep to
the following safety rules.
• Before connecting up, turn of the power supply.
• The sealing of the cable feedthroughs of the SCALANCE W786 is only assured when
• Never wrap insulating tape, adhesive tape or other materials around thinner cables to
• Close all unused openings in the housing seal with the sealing plugs supplied with the
SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
WARNING
the cable has a suitable diameter and adequate tensile strength. Only use cables that
meet the specifications in the section "Cables for the SCALANCE W786". When
connecting up a FO cable, make sure that you use the adhesive sealing foil supplied
with the SCALANCE W786.
achieve the required diameter. In this case, neither the housing seal nor the strain relief
clamps can fulfill their function.
SCALANCE W786. Do not use fillers or any other material under any circumstances.
Connecting up
4.3 Connecting the cables
49