LED
F
Note
If the LED for the WLAN port is not green when the device starts up, although it is activated,
the port is not ready for operation (interface not initialized).
The main reason for this is usually that during commissioning of the SCALANCE W78x
products, a waiting time of up to 15 minutes can occur when the ambient temperature is
below zero. The device is ready for operation at the specified ambient temperature as soon
as the LED for the WLAN interface is lit green.
SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
Color
Description
Access Point Mode:
Green
The WLAN interface is initialized and ready for operation.
Client Mode:
The LED is always off because the 3rd port is not available in client
mode.
Access Point Mode:
Flashing green
The channels are being scanned.
Client Mode:
The LED is always off because the 3rd port is not available in client
mode.
Access Point Mode:
Green flashing
quickly
With 802.11h, the channel is scanned for one minute for primary users
before the channel can be used for data traffic.
Client Mode:
The LED is always off because the 3rd port is not available in client
mode.
Flashing yellow
PRESET-PLUG detected.
Yellow/green
PRESET function completed successfully.
Red
An error occurred during operation with the SCALANCE W786.
Flashing red
Ready to load firmware. The device was either stopped with the reset
button or there is incorrect firmware on the device.