Siemens SCALANCE W786-xPRO Operating Instructions Manual page 111

Table of Contents

Advertisement

● Copy internal Configuration to C-PLUG and Restart
● Load default Configuration to C-PLUG and Restart
● Clean C-PLUG (Low Level Format, Configuration lost)
● Create PRESET PLUG
After making your selection, start the function by clicking the "Modify" button.
C-PLUG error message
If the device detects a C-PLUG error during startup, a message is displayed by Web Based
Management. C-PLUG errors can have two causes:
● The C-PLUG contains bad data or data for a different device type.
● There is no C-PLUG in the device although a C-PLUG was present prior to the last
SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
The configuration in the internal flash memory of the SCALANCE W700 is copied to the
C-PLUG; this is followed by a restart.
This function is required in the following important use case: The device has started up
with a C-PLUG containing a bad configuration or a configuration different from the device.
If you have not yet made any configuration changes after starting up the device, you can
use this function to overwrite the content of the C-PLUG with the original device
configuration from memory.
A configuration with all the factory default values is stored on the C-PLUG. This is
followed by a restart in which the device starts up with these default values.
Deletes all data on the C-PLUG and starts a low-level formatting function. There is no
automatic restart.
Writes configuration data to a PRESET PLUG. For detailed information on this topic, refer
to the section "Configuring with the PRESET-PLUG".
shutdown of the device.
Configuration / project engineering
5.6 Configuration with Web Based Management
111