snmpv3 [E|D]
snmpro [E|D]
getcomm [read
community string]
setcomm [write
community string]
trapcomm [trap
community string]
traps [E|D]
See also
SNMP Config menu command (Page 103)
5.7.2.8

CLI\SYSTEM\SNMP\GROUP menu command

Managing SNMP groups
With the commands in this menu, you manage SNMP groups (creating, deleting etc.).
CLI\SYSTEM\SNMP\GROUP>
Command
add <Name>
[NOAUTH|AUTH|PRIV]
[R|W]
SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
Enables / disables SNMPv3.
Enables / disables
SNMPv1/v2c read only.
Specifies the read community
string, maximum length 63
characters
Specifies the write community
string, maximum length 63
characters.
Specifies the trap community
string, maximum length 63
characters.
Enables / disables SNMPv1
traps
Description
Adds an SNMPv3 group with the
following security settings
NOAUTH
No authentication,
no encryption
AUTH
Authentication with
MD5 or SHA
algorithm, no
encryption
PRIV
Authentication with
MD5 or SHA
algorithm and
encryption with the
DES3 algorithm
Configuration / project engineering
5.7 Configuration with the Command Line Interface
Comment
The special features of SNMPv3 undertake effect after
you disable SNMPv1. Enabling SNMPv3 does not
automatically disable SNMPv1.
The default is "public".
The default is "private".
The default is "public".
Traps are then enabled, if SNMP v1, v2c is also enabled.
Comment
IWLAN/
W744
W746
PB LINK
Write access without read access is not possible.
W747
W78x
W78x
RR
181