Alarm Output Connection
The illustration below is used as an example. The example used is an alarm.
• Connect the ALARM_OUT + on the I/O terminal interface to the 3.3V or 5V connection on the
external alarm device (Blue wire in illustration)
• Connect the ALARM_OUT - on the I/O terminal interface to the Input + connection on the
external alarm device (Red wire in illustration)
• Connect the ALARM_GND - on the I/O terminal interface to the Input - connection on the
external alarm device (Black wire in illustration)
See "Alarm Output Connector" on page 348 for pin assignments.