Managing Snmp Trap Sinks (Clu) - Promise Vess A2600 Product Manual

Vess a-series nvr storage appliance
Table of Contents

Advertisement

Vess A2000 Series NVR Storage Appliance

Managing SNMP Trap Sinks (CLU)

Viewing a List of Trap Sinks
To create a trap sink:
1. Main Menu >> Additional Info and Management >> Software Management >> SNMP
>> Trap Sinks
A list of the current trap sinks appears.
Adding a Trap Sink
To add a trap sink:
1. Main Menu >> Additional Info and Management >> Software Management >> SNMP
>> Trap Sinks >> Create New Trap Sink >> Trap Sink IP address
2. Press the backspace key to erase the current value, then type the new IP address in this field.
3. Highlight Trap Filter and press the spacebar to toggle through the severity levels.
See the Table below.
4. Press Control-A to save the Trap Sink.
Event Severity Levels
Level
Description
Fatal
Non-recoverable error or failure has occurred.
Critical
Action is needed now and the implications of the condition are serious.
Major
Action is needed now.
Minor
Action is needed but the condition is not a serious at this time.
Warning
User can decide whether or not action is required.
Information
Information only, no action is required.