5 SETUP AND PROCEDURES BEFORE OPERATION

5.2 Procedures before operation

Module installation
Install the QD70D in the specified slot.
Wiring
Wire the external device to the QD70D.
(Refer to Section 5.4.)
Intelligent function module switch setting
Make setting using GX Developer.
(Refer to Section 5.6.)
Connection confirmation
Confirm connection using GX Developer or
GX Configurator-PT. (Refer to Section 5.5.)
Drive unit operation confirmation
Make confirmation with a simple program in
the factory-set status. (Refer to Section 5.7.)
Initial setting
Using the FROM/TO instructions, create
an initial value write sequence program.
(Refer to Chapter 7.)
Programming, debugging
Create and confirm a sequence program.
(Refer to Chapter 7.)
5 - 3
This section gives the procedure up to the operation of the QD70D.
Start
Do you use
GX Configurator-PT?
No
System operation
Yes
Initial setting
Using GX Configurator-PT, make initial setting.
(Refer to Section 6.4.)
Do you make auto
No
refresh setting?
Auto refresh setting
Using GX Configurator-PT, make auto refresh
setting. (Refer to Section 6.5.)
MELSEC-Q
Yes
5 - 3