8 OPR CONTROL

8.2.2 Machine OPR method

OPR. 1 OPR method
Near-point dog method
Stopper 1
Stopper 2
Stopper 3
Count 1
Count 2
I/O signal
Zero signal (PG0)
Near-point dog (DOG)
Deviation counter clear
(CLEAR)
Retry switch signal (RTRY)*
* The retry switch signal is needed for the OPR retry function. For details, refer to "Section 8.4 OPR retry function".
8 - 3
The method by which the machine OP is established (method for judging the OP
position and machine OPR completion) is designated in the machine OPR control
according to the configuration and application of the positioning control system.
The following table shows the six methods that can be used for this OPR method.
(The OPR method is one of the items set in the OPR data. It is set in " OPR. 1 OPR
method" of the OPR data.)
Deceleration starts when the near-point dog turns from OFF to ON. (Speed is decreased to
" OPR. 5 Creep speed")
The axis stops on detection of the first zero signal (one pulse of which is output when the
motor turns one revolution, e.g. Zero signal output from the drive unit) after the near-point
dog has turned from OFF to ON, and on completion of the deviation counter clear output,
machine OPR control is completed.
The stopper position is defined as the OP.
After deceleration is started when the near-point dog turns from OFF to ON, the axis is
brought into contact with the stopper at " OPR. 5 Creep speed" to a stop.
After the stop, the time preset in " OPR. 9 OPR dwell time" elapses, and on completion of
the deviation counter clear output, machine OPR control is completed.
The stopper position is defined as the OP.
After deceleration is started when the near-point dog turns from OFF to ON, the axis is
brought into contact with the stopper at " OPR. 5 Creep speed" to a stop.
After the stop, the zero signal (signal that is output on detection of contact with the stopper)
is detected, and on completion of the deviation counter clear output, machine OPR control
is completed.
The stopper position is defined as the OP.
The axis starts at " OPR. 5 Creep speed" from the beginning, and is brought into contact
with the stopper at " OPR. 5 Creep speed" to a stop.
After the stop, the zero signal (signal that is output on detection of contact with the stopper)
is detected, and on completion of the deviation counter clear output, machine OPR control
is completed.
Deceleration is started when the near-point dog turns from OFF to ON, and the axis moves
at " OPR. 5 Creep speed".
After the axis has moved the distance preset in " OPR. 8 Setting for the movement amount
after near-point dog ON" from the position where the near-point dog turned from OFF to
ON, it stops on detection of the zero signal (one pulse of which is output when the motor
rotates one revolution, e.g. Zero signal output from the drive unit), and on completion of the
deviation counter clear output, machine OPR control is completed.
Deceleration is started when the near-point dog turns from OFF to ON, and the axis moves
at " OPR. 5 Creep speed".
The axis stops after moving the distance preset in " OPR. 8 Setting for the movement
amount after near-point dog ON" from the position where the near-point dog turned from
OFF to ON, and on completion of the deviation counter clear output, machine OPR control
is completed.
Wiring of signals required for each OPR method
OPR method
Near-point
dog method
Description
Stopper 1
Stopper 2
: Wiring required
MELSEC-Q
Stopper 3
Count 1
: Wiring may be required –: Wiring not required
Count 2
8 - 3