Confirming The Error Definitions Using System Monitor Of Gx Developer - Mitsubishi Electric QD70D4 User Manual

Q series
Table of Contents

Advertisement

13 TROUBLESHOOTING

13.5 Confirming the error definitions using system monitor of GX Developer

13 - 16
Choosing Module's detailed information in the system monitor of GX Developer allows
you to confirm the error code at axis error occurrence.
(1) Operation of GX Developer
Choose [Diagnostics]
Module's Detailed Information .
(2) Confirmation of error code
The error code stored in " Md. 5 Axis error code" appears in the latest error code
field. (Any of axes 1 to 8)
(By pressing the Error History button, the error code of the error that has
occurred in each axis is displayed in order of axes 1 to 8. Note that this display
does not give a history.)
[System monitor]
[Error display details]
Error code of Axis n
Axis n (1
n
8)
"QD70D module" and choose
[Display format]
Select "Decimal".
(The error codes indicated in
"Section 13.2 List of errors"
are in decimal.)
[Present Error]
Means error code 103
"Software stroke limit +".
MELSEC-Q