4 DATA USED FOR POSITIONING CONTROL
Pr. 6 Bias speed at start
4 - 31
Da. 2 Control method
Set the "control method" for positioning control.
0: No control method
1: 1-axis linear control (ABS)
2: 1-axis linear control (INC)
3: Speed.Position Ctrl. (Forward) ...... Speed-position switching control (forward
4: Speed.Position Ctrl. (Reverse)...... Speed-position switching control (reverse
5: Current value changing
Note) • Refer to "CHAPTER 9 POSITIONING CONTROL" for details of the
control method.
• Setting "0: No control method" will result in the "Setting range outside
control method" error (error code: 506).
Da. 3 ACC/DEC time, Da. 4 DEC/STOP time
Set the acceleration/deceleration time for positioning control.
[" Da. 1 Operation pattern" is "0: Positioning termination" or "1: Continuous
positioning control"]
Da. 3 ACC/DEC time : Set the time taken to reach " Da. 5 Command speed"
Da. 4 DEC/STOP time : Set the time taken to make a stop after reaching
V
Positioning data No. 1
(Continuous positioning control)
Da. 3
run)
run)
from " Pr. 6 Bias speed at start".
" Pr. 6 Bias speed at start" from " Da. 5 Command
speed" at position control completion or axis stop
factor occurrence (axis stop signal ON or error
occurrence).
Positioning data No. 2
(Positioning termination)
Da. 5
Da. 4
Da. 3
Da. 7 Dwell time
MELSEC-Q
Da. 5
t
Da. 4
Da. 7 Dwell time