Table A-5. 2051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Surface Finish
Standard
Q16
Surface finish certification for sanitary remote seals
Toolkit Total System Performance Reports
Standard
QZ
Remote Seal System Performance Calculation Report
Conduit Electrical Connector
Standard
GE
M12, 4-pin, Male Connector (eurofast
GM
A size Mini, 4-pin, Male Connector (minifast
Typical Model Number: 2051CD 2 A 2 2 A 1 A B4$13857 780
(1) 2051CD0 is available only with Output Code A, Process Flange Code 0 (Alternate Flange H2, H7, HJ, or HK), Isolating Diaphragm Code 2, O-ring Code A, and Bolting Option L4.
(2) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(3) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain
materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(4) Requires 0 code in Materials of Construction for Alternate Process Connection.
(5) Not valid with optional code P9 for 4500 psi Static Pressure.
(6) Process Flange limited to Coplanar (codes 2, 3, 5, 7, 8) or Traditional (H2, H3, H7).
(7) Not valid with optional code D9 for RC1/2 Adaptors.
(8) Not valid for optional codes DF and D9 for Adaptors.
(9) "Assemble-to" items are specified separately and require a completed model number.
(10) Available only with output codes A - 4-20 HART and F - F
(11) Not available with Low Power code M.
(12) Available only with 2051CD and 2051CG and output code A - 4-20 mA HART
(13) Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all cast C-276 flanges, all plated CS flanges, all DIN flanges, all Level flanges, assemble-to
manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3 and S4 codes), surface finish certification (Q16 code), and remote seal
system report (QZ code).
(14) Available only with output code W - Profibus PA.
(15) Only available with HART 4-20 mA output (output code A).
(16) Not available with Fieldbus (output code F) or Profibus (output code W).
(17) Local zero and span adjustments are standard unless Option Code J1 or J3 is specified
(18) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA and IE.
(19) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(20) High Performance Option includes 0.04% Reference Accuracy. See
(21) Not valid with Alternate Process Connection options S3, S4, S5, and S6.
(22) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(23) Not available with Alternate Process Connection; DIN Flanges and Level Flanges.
(24) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
Specifications and Reference Data
®
)
®
)
fieldbus.
OUNDATION
Performance Specifications
Appendix A: Reference Data
for details.
June 2012
Standard
Standard
Standard
91