Emerson Rosemount 2051 Wireless Series Reference Manual page 104

Pressure, level, and flow solutions with wirelesshart protocol
Hide thumbs Also See for Rosemount 2051 Wireless Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4102, Rev AA
Table A-10. Rosemount 2051CFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
WP5
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
Lower Power Output
Standard
(13)
C2
0.8-3.2 V dc Output with Digital Signal Based on Hart Protocol
Alarm Limit
Standard
(13)
(14)
C4
NAMUR Alarm and Saturation Levels, High Alarm
(13)(14)
CN
NAMUR Alarm and Saturation Levels, Low Alarm
Hardware Adjustments
Standard
DZ
Digital Zero Sensor Trim Configuration Button
Ground Screw
Standard
(15)
V5
External Ground Screw Assembly
Typical Model Number: 2051CFP D S 010 W1 S 0500 D3 2 A A 1 E5 M5
(1) To improve pipe perpendicularity for gasket sealing, socket diameter is smaller than standard pipe O.D.
(2) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(3) Thermowell Material is the same as the body material.
(4) Does not apply to Process Connection codes T1 and S1.
(5) Not available for bore sizes 0010, 0014, 0020, or 0034.
(6) Not available with DIN Process Connection codes D1, D2, or D3.
(7) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(8) Not available with F
OUNDATION
(9) Not available with Low Power code M.
(10) Available only with output code W - Profibus PA.
(11) The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product Certification code IA.
(12) Only valid with F
fieldbus Output Code F.
OUNDATION
(13) Not available with F
OUNDATION
(14) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(15) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
Specifications and Reference Data
fieldbus (Output Code F) or Profibus (Output Code W).
fieldbus (Output Code F) or Profibus (Output Code W).
Appendix A: Reference Data
June 2012
Standard
Standard
Standard
Standard
117