Reference Manual
00809-0100-4102, Rev AA
Table A-6. 2051T In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
A.6.2
Options
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3
User Configurable Transmit Rate, 2.4 GHz WirelessHART
Antenna and SmartPower
Standard
WP5
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
PlantWeb Control Functionality
Standard
A01
Advanced Control Function Block Suite
PlantWeb Diagnostic Functionality
Standard
D01
F
fieldbus Diagnostics Suite
OUNDATION
Manifold Assemblies
Standard
(4)
S5
Assemble to Rosemount 306 Integral Manifold
Seal Assemblies
Standard
(4)
S1
Assemble to one Rosemount 1199 seal
Mounting Bracket
Standard
B4
Bracket for 2-in. Pipe or Panel Mounting, All SST
Product Certifications
Standard
C6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
E2
INMETRO Flameproof
E3
China Flameproof
(5)
E4
TIIS Flameproof
E5
FM Explosion-proof, Dust Ignition-proof
(5)
E7
IECEx Flameproof, Dust Ignition-proof
E8
ATEX Flameproof and Dust Certification
(5)
I1
ATEX Intrinsic Safety and Dust
I2
INMETRO Intrinsic Safety
I3
China Intrinsic Safety
I5
FM Intrinsically Safe, Division 2
(5)
I7
IECEx Intrinsic Safety
IA
ATEX Intrinsic Safety for FISCO; for F
IE
FM FISCO Intrinsically Safe; for F
K2
INMETRO Flameproof, Intrinsic Safety
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
(5)
K6
CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6 and K8)
(5)
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
(5)
K8
ATEX Flame-proof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and
C6)
(5)
KD
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
(5)
N1
ATEX Type n Certification and Dust
N3
China Type n
(5)
N7
IECEx Type n Certification
Specifications and Reference Data
(Include with selected model number)
fieldbus protocol only
OUNDATION
fieldbus protocol only
OUNDATION
Appendix A: Reference Data
June 2012
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
93