Appendix A: Specifications and Reference Data
June 2012
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Standard
0
Not Applicable or Customer Supplied
Expanded
1
Gate Valve, Carbon Steel
2
Gate Valve, Stainless Steel
5
Ball Valve, Carbon Steel
6
Ball Valve, Stainless Steel
Temperature Measurement
Standard
T
Integral RTD – not available with Flanged model greater than class 600#
0
No Temperature Sensor
Expanded
R
Remote Thermowell and RTD
Transmitter Connection Platform
Standard
3
Direct-mount, Integral 3-valve Manifold– not available with Flanged model greater than class 600
5
Direct -mount, 5-valve Manifold – not available with Flanged model greater than class 600
7
Remote-mount NPT Connections (
Expanded
6
Direct-mount, high temperature 5-valve Manifold – not available with Flanged model greater than
class 600
8
Remote-mount SW Connections (
Differential Pressure Range
Standard
1
0 to 25 in H
2
0 to 250 in H
3
0 to 1000 in H
Transmitter Output
Standard
X
Wireless
Transmitter Housing Material
Standard
P
Engineered polymer
Transmitter Performance Class
Standard
1
1.6% flow rate accuracy, 8:1 flow turndown, 5-yr. stability
Wireless options
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3
User Configurable Transmit Rate, 2.4GHz WirelessHART
PlantWeb Diagnostic Functionality
Standard
WP5
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
108
1
/
-in. NPT)
2
1
/
-in.)
2
O (0 to 62,3 mbar)
2
O (0 to 623 mbar)
2
O (0 to 2,5 bar)
2
(Requires option code X and Engineered Polymer housing code P)
Conduit Entry Size
No conduit entries
Specifications and Reference Data
Reference Manual
00809-0100-4100, Rev AA
Standard
Standard
Standard
Standard
Standard
Standard
Standard