Emerson Rosemount 2051 Wireless Series Reference Manual page 201

Pressure, level, and flow solutions with wirelesshart protocol
Hide thumbs Also See for Rosemount 2051 Wireless Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4100, Rev AA
Table 1. 3051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
P3
Cleaning for <1 PPM Chlorine/Fluorine
Pressure Calibration
Expanded
P4
Calibrate at Line Pressure (Specify Q48 on order for corresponding certificate)
High Accuracy
Standard
(12)
P8
0.04% Accuracy to 5:1 turndown (Range 2-4)
Flange Adapters
Standard
(13)
1
DF
/
-14 NPT flange adapter(s)
2
D3
¼–18 NPT Process Connections (No flange adapters)
Vent/Drain Valves
Expanded
D7
Coplanar Flange Without Drain/Vent Ports
RC
1
/
RC
1
/
Process Connection
4
2
Expanded
(14)
D9
RC ¼ Flange with RC ½ Flange Adapter, CS - SST
Max Static Line Pressure
Standard
P9
4500 psig (310 bar) Static Pressure Limit
Surface Finish
Standard
Q16
Surface finish certification for sanitary remote seals
Toolkit Total System Performance Reports
Standard
QZ
Remote Seal System Performance Calculation Report
Typical Model Number: 3051CD 2 A 2 2 A 1 A B4$13857 780
(1)Wireless output (code X) available in absolute measurement type (Code A) with only range 1-4, 316L SST isolating diaphragm material
(code 2), silicone fill fluid (code 1), and housing code (code P).
(2)Wireless output (code X) available in draft range 0 with only 316L SST isolating diaphragm (code 2), silicone fill fluid (code 1), housing
code (code P), process flange (code 0), glass-filled o-ring (code A), and bolting option (code L4).
(3)Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for
sour refining environments.
(4)Requires 0 code in Materials of Construction for Alternate Process Connection.
(5)Not valid with optional code P9 for 4500 psi Static Pressure.
(6)"Assemble-to" items are specified separately and require a completed model number.
(7)Process Flange limited to Coplanar (codes 2, 3, 5, 7, 8) or Traditional (H2, H3, H7).
(8)Not valid with optional code D9 for RC
(9)Not valid for optional codes DF and D9 for Adaptors.
(10)Panel mounting bolts are not supplied.
(11)Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all Cast Alloy C-276 flanges, all plated CS flanges, all DIN
flanges, all Level flanges, assemble-to manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3
and S4 codes), surface finish certification (Q16 code), and remote seal system report (QZ code).
(12)Only available with Standard 3051. See specification section for more information.
(13)Not valid with Alternate Process Connection options S3, S4, S5, and S6.
Specifications and Reference Data
(3051CD Ranges 2–5 only)
1
/
Adaptors.
2
Appendix A: Specifications and Reference Data
June 2012
Standard
Standard
Standard
Standard
Standard
99

Advertisement

Table of Contents
loading