Appendix A Reference Data; Performance Specifications - Emerson Rosemount 2051 Reference Manual

Pressure transmitter
Hide thumbs Also See for Rosemount 2051:
Table of Contents

Advertisement

Reference Manual
00809-0100-4101
A 
Reference Data
A.1 

Performance Specifications

For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange
(2051C) or 1/2 in. - 14 NPT (2051T) process connections, digital trim values range points.
Applies to 4-20 mA HART
A.1.1 
Conformance To Specification (±3σ (Sigma))
Technology leadership, advanced manufacturing techniques and statistical process control
ensure specification conformance to at least ±3σ.
Reference Accuracy
Models
1)
2051C   
Ranges
2-5
Range 1
2051T
Ranges
1-4
Range 5
2051L
Ranges
2-4
(1)
For Foundation fieldbus transmitters, use calibrated range in place of span.
Reference Manual
output only unless otherwise noted.
®
(
Standard
±0.075% of span
For spans less than 10:1, accuracy =
±0.10% of span
For spans less than 15:1, accuracy =
 
±0.075% of span
For spans less than 10:1, accuracy =
±0.075% of span for spans greater than 5:1
±0.075% of span
For spans less than 10:1, accuracy =
Reference Data
Perform
Option, P8
ance
Ranges
High Accuracy Option, P8
2-5
±0.065% of span
For spans less than 10:1, accuracy =
 
 
 Ranges
 
1-4
High Accuracy Option, P8
±0.065% of span
For spans less than 10:1, accuracy =
 
 
 
 
March 2024
93

Advertisement

Table of Contents
loading