Appendix A: Reference Data
June 2012
Table A-5. 2051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Mounting Bracket
Standard
B1
Traditional Flange Bracket for 2-in. Pipe Mounting, CS Bolts
B2
Traditional Flange Bracket for Panel Mounting, CS Bolts
B3
Traditional Flange Flat Bracket for 2-in. Pipe Mounting, CS Bolts
B4
Coplanar Flange Bracket for 2-in. Pipe or Panel Mounting, all SST
B7
B1 Bracket with Series 300 SST Bolts
B8
B2 Bracket with Series 300 SST Bolts
B9
B3 Bracket with Series 300 SST Bolts
BA
SST B1 Bracket with Series 300 SST Bolts
BC
SST B3 Bracket with Series 300 SST Bolts
Product Certifications
Standard
C6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
(11)
E2
INMETRO Flameproof
(11)
E3
Chine Flameproof
(10)
E4
TIIS Flame-proof
E5
FM Explosion-proof, Dust Ignition-Proof
(11)
E7
IECEx Flameproof, Dust Ignition-proof
E8
ATEX Flameproof and Dust Certification
(11)
I1
ATEX Intrinsic Safety and Dust
(11)
I2
INMETRO Intrinsic Safety
I3
China Intrinsic Safety
(12)
I4
TIIS Intrinsic Safety
I5
FM Intrinsically Safe, Division 2
(11)
I7
IECEx Intrinsic Safety
IA
ATEX FISCO Intrinsic Safety; for F
IE
FM FISCO Intrinsically Safe; for F
(11)
K2
INMETRO Flameproof, Instrinsic Safety
K5
FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2
(11)
K6
CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6 and K8)
(11)
K7
IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
(11)
K8
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
KB
FM and CSA Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and
C6)
(11)
KD
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
(11)
N1
ATEX Type n Certification and Dust
N3
China Type n
(11)
N7
IECEx Type n Certification
Drinking Water Approval
Standard
(13)
DW
NSF drinking water approval
Shipboard Approvals
Standard
SBS
American Bureau of Shipping
88
fieldbus protocol only
OUNDATION
fieldbus protocol only
OUNDATION
Reference Manual
00809-0100-4102, Rev AA
Specifications and Reference Data
Standard
Standard
Standard