Table A-8. Rosemount 2051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Antenna and SmartPower
Standard
WP5
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
Product Certifications
Standard
C6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
E5
FM Explosion-proof, Dust Ignition-proof
(8)
E7
IECEx Flameproof, Dust Ignition-proof
E8
ATEX Flameproof, Dust
(8)
I1
ATEX Intrinsic Safety
I5
FM Intrinsically Safe, Division 2
IA
ATEX FISCO Intrinsic Safety; for F
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
(8)
K6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
(8)
K8
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of K5 and
C6)
(8)
KD
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
(8)
N1
ATEX Type n
Sensor Fill Fluid and O-ring Options
Standard
L1
Inert Sensor Fill Fluid Note: Silicone fill fluid is standard.
L2
Graphite-Filled (PTFE) O-ring
LA
Inert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring
Shipboard Approvals
Standard
SBS
American Bureau of Shipping
Display and Interface Options
Standard
(9)
M4
LCD Display with Local Operator Interface
M5
LCD Display
Transmitter Calibration Certification
Standard
Q4
Calibration Certificate for Transmitter
Quality Certification for Safety
Standard
(11)
QS
Prior-use certificate of FMEDA data
Transient Protection
Standard
(10)
T1
Transient terminal block
Manifold for Remote Mount Option
Standard
F2
3-Valve Manifold, Stainless Steel
F6
5-Valve Manifold, Stainless Steel
Expanded
F1
3-Valve Manifold, Carbon Steel
F3
3-Valve Manifold, Alloy C-276
F5
5-Valve Manifold, Carbon Steel
F7
5-Valve Manifold, Alloy C-276
Specifications and Reference Data
fieldbus protocol only
OUNDATION
Appendix A: Reference Data
June 2012
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
107