Appendix A: Specifications and Reference Data
June 2012
Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
3
0 to 1000 in H
Transmitter Output
Standard
X
Wireless
Transmitter Housing Material
Standard
P
Engineered polymer
Transmitter Performance Class
Standard
1
up to ±1.75% flow rate accuracy, 8:1 flow turndown, 5-year stability
Wireless options
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3
User Configurable Transmit Rate, 2.4GHz WirelessHART
PlantWeb Diagnostic Functionality
Standard
WP5
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
Options
(Include with selected model number)
Transmitter Body / Bolt Material
Expanded
GT
High Temperature (850 °F / 454 °C)
Temperature Sensor
Expanded
(2)
RT
Thermowell and RTD
Optional Connection
Standard
G1
DIN 19213 Transmitter Connection
Pressure Testing
Expanded
(3)
P1
Hydrostatic Testing with Certificate
Special Cleaning
Expanded
P2
Cleaning for Special Services
PA
Cleaning per ASTM G93 Level D (Section 11.4)
Material Testing
Expanded
V1
Dye Penetrant Exam
Material Examination
Expanded
V2
Radiographic Examination
Flow Calibration
Expanded
(4)
WD
Discharge Coefficient Verification
118
O (0 to 2,5 bar)
2
(Requires option code X and Engineered Polymer housing code P)
Conduit Entry Size
No conduit entries
Specifications and Reference Data
Reference Manual
00809-0100-4100, Rev AA
Standard
Standard
Standard
Standard

Advertisement