Display Problems - Digital Equipment DEC 3000 500X AXP Owner's Manual

Hide thumbs Also See for DEC 3000 500X AXP:
Table of Contents

Advertisement

Display Problems

If there appears to be some problem with your monitor display,
Overview
try to locate the problem in this section.
If your monitor displays diagnostic startup tests when you turn
Cursor in
Corner of
on your system, but then displays only the cursor in the lower
left-hand corner of the screen (rather than displaying the system
Screen
startup test information), the alternate console switch is in the
wrong position.
Corrective
Locate the alternate console switch, on the rear of the system
Action
unit. Refer to Figure 11–2 to see the switch position. If the
switch is set to the left, it is incorrect for a workstation.
Complete these steps to change the switch position:
1. Turn off the system unit (power switch to the O position).
2. Move the alternate console switch to the right. Use a small
3. Turn on the system unit (power switch to the | position).
pointed object to set the switch, but do not use a pencil; the
graphite will damage the switch. See Chapter 11 for more
information.